HEAT TRANSFER CHARACTERISTICS OF THE TWO-PHASE CLOSED THERMOSYPHON (WICKLESS HEAT PIPE)

Get access (open in a dialog) DOI: 10.1615/IHTC7.930
pages 187-192

Abstrakt

Steady-state heat transfer characteristics and heat transfer limits (dry-out) for a vertical stainless steel tubular two-phase closed thermosyphon with Freon-113 working fluid are reported as a function of certain geometric parameters and liquid fill quantity. Condenser section heat transfer characteristics agreed reasonably well with existing laminar film condensation correlations and were found to be independent of the evaporator section, except for larger liquid fills. Evaporator characteristics were quite complex and appeared, under some conditions, to be coupled to condenser characteristics through effects of system pressure and/or surface waves present on the descending condensate film. A laminar thin film evaporation model was found to give reasonable agreement with local evaporator temperature measurements in those regions of the evaporator where a continuous film apparently persisted. The measured heat transfer characteristics are interpreted relative to an earlier investigation by the authors in which liquid flow characteristics in a similar device were visually and photographically observed.